Tech: +49 6081 583 460

Order: +49 6081 583 470

TAE Antriebstechnik • Raiffeisenstrasse 10 • D-61250 Usingen

Brake choppers

TECHNICAL SPECIFICATIONS

Output: 5,5 kW .. 375 kW
Voltage: 200 .. 440 VDC und 450 .. 800 (1000) VDC
Ambient temperature: 0 .. 40°C
Humidity: up to 90%
Operating height: up to 1000 m above sea level

The brake choppers BC2.1, BC3.1 and BC4.1 are available in the voltage ranges of 200 - 440 VDC and 450 - 800 VDC (optionally up to 1000 V) in the performance range of 5.5 - 375 kW with the following characteristics:

  • Modern IGBT technology, with short-circuit monitoring
  • Simple connection, no adjustments necessary
  • Compact construction sizes
  • Robustmetal housing, optimal EMC compatibility (electromagnetic compatibility)
  • Emergency stop possible even in the event of a power failure since the control electronics are supplied  from the intermediate circuit

The devices do not require control voltage and are easy to install. LEDsindicate the operating state.

MODELS

  • IP 20 sheet metal housing
  • Operating, error and ready indicators via LEDs
  • Minimal voltage ripple on the intermediary circuit (< 5 V) with an active brake chopper
  • Options: Parallel or series connection of the trigger signal using master/ slave function, ready for operation and chopper active via optocoupler output, lock output stage and trigger signal via optocoupler input

AREAS OF APPLICATION

  • U-Drive
  • Frequency converter
  • Battery charging devices
  • Crane application, lifting systems
  • Traction drives
  • Centrifuges

Ask our engineers and technicians about the customer-specific solution to your problem!

Torsten Meißner

Development

+49 6081-583-415
torsten.meissner@pikatron.de